The Global Leader in Temperature and Gas Sensing Solutions
Search
  • Impac
  • Mikron
  • Luxtron
  • Innova
  • Andros

Downloads:
Download the Acrobat Reader here:

Innova 1412

The LumaSense Photoacoustic Field Gas-Monitor Innova - 1412 is a highly accurate, reliable and stable quantitative field gas monitor. Its measurement principle is based on the photoacoustic infrared detection method. This means that the 1412 can measure almost any field gas that absorbs infrared light.

Appropriate optical filters (up to 5 + water vapor) are installed in the Field Gas Monitor - Innova 1412's filter carousel so that it can selectively measure the concentration of up to 5 component gases and water vapor in any air sample. Further, Field Gas Monitor Innova- 1412 can compensate for interference between the measured field gases, using the unique Cross-compensation feature. The 1412's detection limit is field gas-dependent but typically in the 10-² ppm region.
Principle of PAS Measurement System
Principle of PAS Measurement System


Field Gas Monitor - Innova 1412 Uses


  • Quantitative analysis of up to 5 components and water vapor in gas mixtures
  • Indoor air-quality and ventilation measurements
  • Ventilation measurements using tracer-gas
  • Occupational health and safety measurements - of possible production or accumulation of toxic/carcinogenic substances in working areas
  • Monitoring of anaesthetic gases in hospitals
  • Emission monitoring of exhaust from chemical processes

Field Gas Monitor - Innova 1412 Features


  • Selectively measures a wide range of gases/vapors
  • Linear response over a wide dynamic range
  • High stability (low drift) makes calibration only necessary 1-2 times a year
  • Extremely reliable due to self-testing procedures
  • User-friendly procedures for calibrating the monitor, presenting and analyzing measurement data via the PC user interface
  • Accurate – compensates for temperature fluctuations, water-vapor interference and interference from other known gases
  • Extremely low-volume flushing possible
  • Operates immediately - no warm-up time is necessary
  • Presents measurement data both in tabular and graphic formats – up to 5 gas concentration graphs displayed, simultaneously

INNOVA Gas Detection Limits


The optical filters used in Field Gas Monitor - Innova 1412 display different characteristics while sharing a basic design. Each filter comprises three separate infrared elements; a narrow-band pass element, a short-wave pass element and a wide-band pass element. The narrow-band pass element has very specific transmission characteristics defined by the short-wave pass and wide-band pass elements, which prevents transmission of light at other wavelengths.

Read more about Detection Limits or order our Detection Limits Chart.