Sensing solutions by Lumasense Technologies
Multi-gas Monitor - Innova 1314
Fermentation Monitor - Innova 1313
Multi Point Sampler - Innova 1309
Multi Sampler and Doser - Innova 1303
SF6 Leak Detector
Anesthesia Gas Monitoring Subsystem - Andros 4800
Emissions Analyzer - Andros 6500

Photoacoustic Field Gas Monitor - Innova 1412

The LumaSense Photoacoustic Field Gas-Monitor Innova - 1412 is a highly accurate, reliable and stable quantitative gas monitor. Its measurement principle is based on the photoacoustic infra-red detection method. This means that the 1412 can measure almost any gas that absorbs infra-red light.
Appropriate optical filters (up to 5 + water vapor) are installed in the 1412's filter carousel so that it can selectively measure the concentration of up to 5 component gases and water vapor in any air sample. Further, the instrument can compensate for interference between the measured gases, using the unique Cross-compensation feature. The 1412's detection limit is gas-dependent but typically in the 10-² ppm region

Principle of PAS Measurement System

Uses

  • Quantitative analysis of up to 5 components and water vapor in gas mixtures
  • Indoor air-quality and ventilation measurements
  • Ventilation measurements using tracer-gas
  • Occupational health and safety measurements - of possible production or accumulation of toxic/carcinogenic substances in working areas
  • Monitoring of anaesthetic gases in hospitals
  • Emission monitoring of exhaust from chemical processes

Features

  • Selectively measures a wide range of gases/vapors
  • Linear response over a wide dynamic range
  • High stability (low drift) makes calibration only necessary 1-2 times a year
  • Extremely reliable due to self-testing procedures
  • User-friendly procedures for calibrating the monitor, presenting and analyzing measurement data via the PC user interface
  • Accurate – compensates for temperature fluctuations, water-vapor interference and interference from other known gases
  • Extremely low-volume flushing possible
  • Operates immediately - no warm-up time is necessary
  • Presents measurement data both in tabular and graphic formats – up to 5 gas concentration graphs displayed, simultaneously

INNOVA Gas Detection Limits

The optical filters used in the instruments display different characteristics while sharing a basic design. Each filter comprises three separate infra-red elements; a narrow-band pass element, a short-wave pass element and a wide-band pass element. The narrow-band pass element has very specific transmission characteristics defined by the short-wave pass and wide-band pass elements, which prevents transmission of light at other wavelengths.

Read more about Detection Limits or order our Detection Limits Chart.

 

 LumaSense Gas Monitor Innova 1412

Further Information click here