校准源 M310-HT
Portable, compact low temperature blackbody calibration source with a large surface area.
Ambient +5 ... 450 °C (+9 ... 842 °F)
Key Features
- Excellent general purpose calibration
- High emissivity 1.00 effective @ 8 ... 14 µm
- Highly uniform
- Large aperture (3” diameter)
- High accuracy, high resolution
- Excellent stability ± 0.3 °C per 8 hour period
- Manufactured and tested to meet rigid quality control standards
- Furnished with certificate of calibration traceable to NIST
- RS232 serial communication included
Details
The M310-HT is a portable blackbody calibration source utilizing a digital indicating temperature controller that may be set to any temperature between ambient +5 °C to 450 °C (+9 to 842 °F). A precision RTD temperature sensor is embedded in the blackbody emitter, providing high accuracy and repeatability.
The temperature controller uses the industry standard PID algorithms to control the emitter temperature to within 0.3 °C of the set points. The blackbody emitter mechanism uses a resistive heating device that provides long life, short stabilization times, and stable temperature control.
Temperature set points are changed by pressing the up or down arrow buttons on the controller. The lower display is the set point and the upper display is the actual blackbody emitter temperature.
Typical Calibration Applications
- Infrared Temperature Sensors
- Infrared Thermal Imaging Systems
- Spectrographic Analyzers
- Radiometers
- Flux Meters
Technical Specifications
Measurement Specifications | |
---|---|
Temperature Range | Ambient + 5 ... 450 °C (+ 9 ... 842 °F) |
Temperature Uncertainty1 | 0.25% of reading ± 1 °C |
Display Accuracy vs. NIST Calibration | See supplied NIST calibration report |
Temperature Resolution | 0.1 °C |
Stability2 | 0.3 °C per 8 hour period |
Source Non-Uniformity | Approximately ± 1 °C @ 250 °C or ± 2 °C @ 400 °C |
Heated Emitter Shape | Flat Plate |
Exit Port Diameter | 76 mm (3.00 in) |
Emissivity | 1.00 effective emissivity at 8 ... 14 μm |
Standard Calibration Method | Radiometric at 8 ... 14 μm |
Temperature Sensor | Precision platinum RTD |
Warm-up Time | < 30 minutes ambient to 400 °C |
Slew Rate to 1 °C Stability | Approximately 6 min for a + 50 °C change |
Slew Rate to 0.1 °C Stability | Approximately 10 min for a + 50 °C change |
Communication / Interface | |
---|---|
Remote Set Point | Via RS232 |
Method of Control | Digital PID Controller |
Environmental Specifications | |
---|---|
Operating Ambient Temperature | 0 ... 44 °C (30 ... 110 °F) |
Cooling | Fan cooled, air inlet on rear panel |
Operating Humidity | 90% RH max, non-condensing |
Dimensions (H x W x D) | 207.3 mm x 280.4 mm x 266 mm (8.2” x 11” x 10.5”) |
Weight | 5.6 kg (12.4 lbs) |
CE Certified | Yes |
Electrical | |
---|---|
Power Requirements | 115 V AC ± 10% 50 & 60 Hz 920 VA fused max, 600 W heater (230 V AC Optional) |
1 Accuracy calibration performed radiometrically, the uncertainty of emissivity and transfer standard are already included.
2 Provided stable AC mains voltage and minimum air flow across the exit port or emitter plate.