MIKRON Thermal Imager
MCS640-HD

Fixed installation thermal imaging system for high-temperature applications. The camera detects temperatures in ranges between 600 and 3000 °C. Designed to withstand ambient temperatures from 0°C to 50 °C without external cooling.

Thermal imaging MC S640 HD View
Thermal imaging MC S640 HD Back View

Key Features

  • Temperature ranges:
    Ranges between 600...1600 °C or 
    Ranges between 800...3000 °C
  • Uncooled, fully radiometric detector (UFPA)
  • Spectral range: NIR (short wavelength), customer specific adaptation on request
  • Display of temperature at 307.200 measurement points (640 x 480 pixel)
  • Unique measurement accuracy of 0,5% of reading
  • Display of images in real-time at 60 Hz (60 images per second)
  • 1000 Mbit/s Gigabit Ethernet data transmission
  • Compact in size with a small weight of 0.7 kg

Documentation

Technical Data

Configurations

MCS640/I5 Filter (780 to 1080 nm)

MCS640/I1 Filter (850 nm)

MCS640/V Filter (650 nm)

MCS640/I4 Filter (750 nm)

MCS640/I8 Filter (1080 nm)

Standard Temperature Ranges 600 to 1600 °C (MB16) or 800 to 3000 °C (MB30) in up to 4 sub-ranges

Sub Ranges

MB16: 600 to 850, 700 to 1000, 850 to 1250, 1100 to 1600

MB30: 800 to 1150,1000 to 1500, 1350 to 2050, 1900 to 3000 

Sensitivity / NETD 1° at 600 °C

IR Detector

640 x 480 pixels; Silicon

Image Update Rate 60 Hz (fps; frames per second)
Emissivity

10.0 to 100.0% adjustable via interface in steps of 0.1% (for full frame camera picture) 

Transmittance 10 to 100 % (in application software)
Uncertainty (Accuracy) +/- 0.5% of reading in °K
Repeatability 0.1% of measured value in °K + 1°K
Protection Class IP65 (IEC 60529); NEMA 4
Shock Resilience 30G (IEC60068-2-29/JIS C 0042)
Vibration Resilience 3G (IEC60068-2-6/JIS C 0040)
Power Supply/Consumption 24V DC, 1A
Power Consumption 10W Typical, 13W Max
Analog Output None 
Digital Interface Gigabit Ethernet (1000 MBit/s)
Connector 12 pin power connector; RJ45 Ethernet connector
Isolation Power supply and digital interface are galvanically isolated from each other
Typical Weight 3.0kg (6.6 lbs) (depends on final lens configuration)
Ambient Temperature 0 to 50 °C
Storage Temperature -40 to 70 °C
Relative Humidity Non condensing conditions
Housing Aluminum extrusion
CE-label According to EU directives about electromagnetic immunity

 

 

 

MIKRON Thermal Imager MCS640-HD
Optics HFOV * VFOV IFOV
10.8° Standard 10.8°Optics List SpacerxOptics List Spacer8.1° 0.3 mrad
5.4° Tele (2x) 5.4°Optics List SpacerxOptics List Spacer 0.15 mrad
3.5° Tele (3x) 3.5°Optics List SpacerxOptics List Spacer2.6° 0.1 mrad
22.5° Wide angle 22.5°Optics List SpacerxOptics List Spacer17° 0.6 mrad
33.3° Wide angle 33.3°Optics List SpacerxOptics List Spacer25.3° 0.9 mrad
40.4° Wide Angle 40.4°Optics List SpacerxOptics List Spacer30.9° 1.1 mrad

Field of View Calculation
Distance mm
Pixel Size IFOV mm  
3 * 3 Pixel MFOV mm  
Width HFOV mm  
Height VFOV mm  

Find Your Local Representative