IMPAC Pyrometer
IN 140/5
IN 140/5-L
IN 140/5-H

Highly accurate, fully digital, fast Digital pyrometer for measurement of glass surfaces with a spectral response of 5.14 µm. Temperature ranges between 250 and 2500 °C

 

IMPAC Pyrometer IN 140/5
IMPAC Pyrometer IN 140/5 (Front)
IMPAC Pyrometer IN 140/5 (laser)
IMPAC Pyrometer IN 140/5 (Laser back)
IMPAC Pyrometer IN 140/5 (View finder)
IMPAC Pyrometer IN 140/5 (View finder side)
IMPAC Pyrometer IN 140/5 (different optics)

Key Features

  • Temperature ranges between 250 and 2500 °C
  • Very short response time, min 10 ms
  • Extremely small spot sizes, min 0.9 mm
  • Focusable optics
  • Optimized thru-lens view finder or laser targeting light
  • Built-in digital display
  • Interface RS232 / RS485 switchable
  • Test current output

Details

The IN 140/5 is a digital pyrometer for non-contact temperature measurement of glass and quartz glass surfaces with temperature ranges between 250 and 2500 °C.

The instrument is characterized by a very short response time and extremely small spot sizes. Thus it is applicable for fast measuring tasks and for the measurement of smallest objects.

The type IN 140/5-L is equipped with a optics with better field of view (optics 2-NL).

The high speed version IN 140/5-H has a shorter response time of only 10 ms.

For optimal match of the instrument to the application (size of the measuring object, measuring distance) different focusable optics are available. The exact alignment of the measuring object will be achieved by a laser targeting light or a optimized thru-lens view finder.

The pyrometer is equipped with a display which shows in measuring mode the current temperature. Additionally all parameters can be read if they are changed via the integrated keys at the instrument.

Via serial interface and the provided software InfraWin the temperature can be displayed and stored on a PC, parameterizing can also be done. The diagnostics function allows to check pyrometer and wiring.

Typical Applications

  • Flat glass fabrication
  • Bulb production
  • Car glass assembly
  • Glass bending

Documentation

Technical Data

 
Temperature ranges:

MB 14    250 - 1400 °C       

MB 15    450 - 1500 °C 

MB 16    300 - 1600 °C       

MB 25     500 - 2500 °C 

Sub range: any range adjustable within the temperature range, minimum span 51°C
Data handling: digital

Spectral range:

5.14 µm (narrow band, for glass surfaces)

IR detector: Thermopile

Power supply:

24 V AC or DC (14 to 30 V AC or DC) (AC: 48 to 62 Hz)

Power consumption: max. 1.2 W
Analog output: 0 - 20 mA or 4 - 20 mA (linear), switchable; test current 10 mA or 12 mA by pressing test key
Load: 0 to 500 ?
Digital Interface: RS232 or RS485 addressable (half duplex), switchable; baud rate 1200 up to 115200 Bd

Resolution:

 

0.1 °C on interface; 0.1 °C/°F (450 to 999 °C / 842 to 999 °F), 1°C (= 1000 °C/°F) on display;

< 0.1% of the adjusted temperature sub range at the analog output

Isolation: power supply, analog output and digital interface are galvanically isolated from each other
Operation signal: green LED
LC display: illuminated LC display for temperature indication or parameter settings
Parameters: emissivity, exposure time, analog output, temperature sub range, settings of the maximum value storage, address, baud rate, internal temperature of the pyrometer.
Emissivity ε: 10 ... 120% adjustable in the instrument or via interface in steps of 0.1%
Exposure time t90:

IN 140/5; IN 140/5-L:           40 ms; adjustable up to 0.05 s; 0.25 s; 1 s; 3 s; 10 s

IN 140/5-H:                           10 ms; adjustable up to 0.05 s; 0.25 s; 1 s; 3 s; 10 s

Maximum value storage: built-in single or double storage. Clearing with adjusted time tclear (off; 0.01 s; 0.05 s; 0.25 s; 1 s; 5 s; 25 s), extern, via interface or automatically with the next measuring object
Uncertainty: (ε = 1, t90 = 1 s)

up to 1300 °C:      0.6% of reading in °C or 2 °C      (Tamb. = 15 - 30 °C) *)

                             1% of reading in °C or 3 °C         (Tamb. = 0 - 15 or 30 - 70 °C) *)

above 1300 °C:    0.8 % of reading in °C                 (Tamb. = 15 - 30 °C)

                             1.2 % of reading in °C                 (Tamb. = 0 - 15 or 30 - 70 °C)

*) whichever value is greater. The instrument must be at a constant ambient temperature for a minimum of 30 minutes

Repeatability (ε = 1, t90 = 1 s): 0.3% of measured value in °C

Noise Equivalent Temperature Difference (NETD):

(ε = 1, t90 = 1 s) Tamb.=10...40 °C)

MB 15 / 25:    at t90 = min: 1.2 °C         (at 500 °C measuring temperature)

                        at t90 = min: 0.6 °C        (at 1200 °C measuring temperature)

MB 14 / 16:    at t90 = min: 0.7 °C        (at 310 °C measuring temperature)

                        at t90 = min: 0.2 °C        (at 500 °C measuring temperature)

                        at t90 = min: 0.15 °C      (at 1200 °C measuring temperature)

Sighting: thru-lens view finder or laser targeting light (max. power level < 1 mW, l = 630-680 nm, CDRH class II)
Ambient temperature: 0 to 70°C 
Storage temperature: -20 to 80°C
Rel. humidity non-condensing conditions
Protection class: IP65 (DIN 40050)
Weight: approx. 550 g
CE-label: according to EU directives about electromagnetic immunity

 

 

IMPAC Pyrometer IN 140/5 IN 140/5-L IN 140/5-H
IN 140/5 & 140/5-H (MB 14 & 16) Foc. Optics 1-N a=100...128 mm
IN 140/5 & 140/5-H (MB 14 & 16) Foc. Optics 2-N a=187...322 mm
IN 140/5 & 140/5-H (MB 14 & 16) Foc. Optics 3-N a=362...2170 mm
IN 140/5 & 140/5-H (MB 15 & 25) Foc. Optics 1-N a=100...128 mm
IN 140/5 & 140/5-H (MB 15 & 25) Foc. Optics 2-N a=187...322 mm
IN 140/5 & 140/5-H (MB 15 & 25) Foc. Optics 3-N a=362...2170 mm
IN 140/5-L (MB 14 & 16) Foc. Optics 2-NL a=159...235 mm
IN 140/5-L (MB 15 & 25) Foc. Optics 2-NL a=159...235 mm
IN 140/5-L (MB 15) Fixed Optics a=163 mm

Display of optical path:

Find Your Local Representative

To find a service for your product or to buy a new one.

Turn-key Service and Support