OEM Gas Analyzer ANDROS 6552

Available with two gas channels, the Andros 6552 can be configured for specific types of refrigeration plants or as a general purpose device that can be applied to any type or combination of refrigeration systems that may employ Freons and Carbon Dioxide.

OEM Gas Analyzer ANDROS 6552 View

Key Features of Andros 6552 Gas Analyzer

OEM gas sensor detects Freon refrigerants and Carbon Dioxide for leak detection and other applications

  • Measure up to 5 gases: 3 via NDIR and 2 via plug-in sensors
  • RS232 or USB
  • Most types of Freons
  • Field upgradable to measure additional gases

Documentation

Benefits of Andros 6552 Gas Analyzer

Highly Accurate Calibration

Every Andros 6552 system is individually calibrated for operation from 0°C to 50°C over the entire range of specified concentrations. The results of this intensive calibration process are stored within each system providing the most accurate analysis possible. This attention to detail provides a highly accurate factory calibration of the NDIR analyzer. Andros is so confident in our factory calibration that our customers need never calibrate the NDIR analyzer again.

The Andros 6552 is designed to meet or exceed EN 14624,“performance of mobile leak detectors and of room controllers of halogenated refrigerants”.

High Stability: Rapid Warm-Up

The enhanced optics and electronics of the 6552 have virtually eliminated zero drift after the initial warm up period. The temperature and pressure compensation eliminates the major causes of span drift in many NDIR instruments.

Unique Optical Architecture

The Andros 6550 Series offers greater design flexibility to OEMs due to its small overall size, our ability to customize subsystem designs to your specifications, and low power consumption. Our analyzer can be fitted into a wide variety of enclosures.

Comprehensive Software Architecture

The Andros Operating System (OS) software and communications protocol is designed to make system integration simple and fast.

 

Technical Data

 
Response time Response times are specified at a sample flow rate of 1 liter per minute through the 6552 sample cell.
Data refresh rate 1 second
Warm-up time 30 minutes fully stable, 3 minutes for reduced accuracy unless zeroed prior to taking measurement
Operating Temperature 0° - 70°C (32° - 158° F), accuracy not specified > 50°C
Operating humidity To 95% RH (Non-condensing)
Operating altitude -300 to 3,000m (-1,000 to 10,000 ft)
Host communication USB or RS232C asynchronous serial; 19,200 bps or 9,600 bps (default is 19,200)
Size 19.18 cm L, 7.37 cm W, 5.03 cm H (7.55 x 2.90 x 1.98 in)
Weight 0.3 kg (0.8 lb)
Input power +12 Volts DC nominal (+9 to +16)
Power consumption 1.8 Watts average at 12 VDC
Warranty 1 year parts and labor warranty
Compliance Designed to meet or exceed EN 14624,“performance of mobile leak detectors and of room controllers of halogenated refrigerants”
Standard freons available: R22, R134A, R404A, R407C, R410A, R507, R422A, R422D

Specifications 

Measurement Method Gas Resolution Measurement Range Accuracy Precision Response Time
NDIR (Non-Dispersive Infrared) on board Most CFC, HFC and HCFC refrigerants 1 ppm 1 to 100 ppm ±4 ppm abs. or ±3% rel. ±4 ppm abs. or ±3% rel. T90 & T10 <3 Seconds
101 to 1,000 ppm ±5% rel.
1,001 to 10,000 ppm +/- 8% rel. ±3% rel.
CO2 0.01% 0.01% to 2.00% ±0.02% abs. or ±3% rel. ±0.02% abs. or ±3% rel. T90 & T10 <3 Seconds
2.01% to 20.00% ±5% rel.
Electrochemical sensors via connector O2 performance dependent upon electrochemical sensor model
NOx