IMPAC Série 5 avec caméra TV intégrée

The digital pyrometers IS 5, IGA 5, ISQ 5 and IS 5/F are also available with integrated TV camera module.

IMPAC Série 5 avec caméra TV intégrée
IMPAC Série 5 avec caméra TV intégrée

Principales Caractéristiques

  • Video Signal: BAS-Signal approx. 1Vss at 75 Ohm, CCIR, 50Hz
  • Resolution: 628x583 Pixel, black and white
  • Illumination Control: automatic, additionally controlled by the measuring temperature in 3 steps
  • Field of View: approx. 10% x 14% of the adjusted measuring distance
  • Connection Video-Signal: SCART- or Cinch plug separate plug at the pyrometer, not galvanically isolated from the pyrometer’s power supply
  • Date/Time: Real time clock with minimum 3 days buffer
  • Screen Inserts: circular target marker Instrument’s number or text to your choice (max 12 Characters) Time and/or Date (switchable)
  • IS / IGA 5-TV: Measured Temperature, Emissivity
  • ISQ 5-TV: Measured Temperature, Emissivity Slope ε1/ε2, Single Channel Temperature with Emissivity
  • IS 5/F-TV: Flame Temperature, Optical Thickness, Soot Factor and Emissivity

Détails

The Video/Camera/Module is an enhancement for the Series 5 pyrometers. Dimensions and electrical details correspond to the standard pyrometer with laser pilot light. Please find electrical and mechanical accessories in the data sheet for the standard pyrometer.

Documentation

Technical Data
 

Temperature range:

IGA 5-TV

MB 18       350 ... 1800°C

MB 20       250 ... 2000°C

MB 25       400 ... 2500°C

IS 5-TV

MB 20 650 ... 1800°C

MB 25 800 ... 2500°C

ISQ 5-TV

MB 14 600 ... 1400°C

MB 18 700 ... 1800°C

MB 25 800 ... 2500°C

MB 30 1000 ... 3000°C

IS 5/F-TV

MB 14 600 ... 1400°C

MB 18 700 ... 1800°C

MB 25 800 ... 2500°C

MB 30 1000 ... 3000°C

Video Signal: BAS-Signal approx. 1Vss at 75 Ohm, CCIR, 50Hz
Resolution: 628x583 Pixel, black and white
Illumination Control: Automatic, additionally controlled by the measuring temperature in 3 steps
Field of View: Approx. 10% x 14% of the adjusted measuring distance
Connection Video-Signal: SCART- or Cinch plug, separate plug at the pyrometer, not galvanically isolated from the pyrometer’s power supply
Date/Time: Real time clock with minimum 3 days buffer
Screen Inserts: Circular target marker, Instrument’s number or text to your choice (max 12 Characters), Time and/or Date (switchable)
IS / IGA 5-TV: Measured Temperature, Emissivity
ISQ 5-TV: Measured Temperature, Emissivity Slope ε1/ε2, Single Channel Temperature with Emissivity
IS 5/F-TV: Flame Temperature, Optical Thickness, Soot Factor and Emissivity

 

Trouvez votre représentant local

Service pour produit existant ou acheter un nouveau produit

Support client et offre de service

Trouver nos offres de service de maintenance / d’étalonnage sur site.